Manager - Electrical Engineering - Ports & Terminals - Nhava Sheva
DP World Sheva, Maharashtra, India
Transportation, Logistics, Supply Chain and Storage · 10,001+ employees
Applying here? Try the free cover letter tool — paste this posting and your résumé, no account needed.
About the role
The manager is responsible for the safe, reliable, and uninterrupted operation of high-voltage substations through preventive, predictive, and corrective maintenance. They also oversee vendor management, spare parts inventory, and the verification of electricity billing and tariff compliance.
What they look for
Requirements
Candidates must possess a Bachelor's degree and strong technical knowledge of HV safety, arc flash hazards, and electrical compliance standards. The role requires expertise in maintaining transformers, circuit breakers, switchgear, and protection relays, alongside proficiency in statutory regulatory norms.
Full description
Carry out routine checks and inspections and Analyse test results and recommend corrective measures of:
- Power transformers – oil level, temperature, silica gel, OLTC operations, cooling fans, radiators.
- HV/MV circuit breakers – VCB, ACB, SF6, GIS.
- CTs, PTs, surge arresters, isolators, bus systems.
- HV/LV switchgear, protection panels, and control wiring.
- Transformer IR, Tan delta, BDV, DGA (Dissolved Gas Analysis), winding resistance.
- Breaker timing tests, contact resistance, insulation resistance.
- Thermography for hotspots on cables, busbars, panels.
Fault Analysis, Troubleshooting & Repair
- Respond to electrical breakdowns in substations and carry out root‑cause analysis.
- Diagnosed faults related to:
- Protection relay trips
- Transformer alarms or abnormal conditions
- Breaker malfunctions
Vendor Management & Spares
- Coordinate with OEMs for servicing major equipment.
- Maintain stock of relays, breaker spares, transformer accessories, and critical components.
- Units consumed (kWh / kVAh)
- MD charges
- TOD slabs (if applicable)
- Power factor incentives/penalties
- Wheeling & cross-subsidy charges
- Electricity duty and taxes
- Actual substation meter readings
- HT metering logs
- TOD consumption breakdown
- Overbilling
- Incorrect tariff application
Verify HT Electricity bills thoroughly:
Cross-check billing with:
Identify anomalies such as:
Safety, Arc‑flash Management & Compliance
Ensure compliance with:
- CEA Regulations (as applicable to operation & maintenance of electrical installations)
- Ensure all substation equipment, installations, and work practices comply with the CEA Regulations.
- Statutory norms from CEIG and State Electricity Board
- IS/IEC/IEEE safety standards
- Lead safety audits,
- HIRA/JSA preparation, and corrective actions.